PTF No.:T380B123
ALOGRENO utility ends unintentionally at the middle of the steps. |

| REGISTERED DATE: |
2004/08/31 |
 |
| CATEGORY: |
Utility |
 |
| CONDITION: |
When there is an inconsistency in the Management Database. |
 |
| PROBLEM DESCRIPTION: |
When condition is met, RC=04 is returned at STEP040 and ALOGRENO utility ends unintentionally because COND parameters of the following steps are specified without stepname to be tested. |
 |
| TEMPORARY ACTION: |
None |
 |
| PROBLEM CONCLUSION: |
The procedures are corrected to specify stepname to be tested for COND parameters of EXEC statements. |
 |
| PREREQUISITE PTF: |
None |
 |
| PROGRAM: |
None |
 |
| CATALOGED PROCEDURE: |
ALOGIUPD, ALOGRENO |
 |
| NECESSARY ACTION: |
After changing the procedures using I380B123, execute ALOGIUPD or ALOGRENO. |
 |
| AMENDING PTF: |
None |
 |

|
 |