PTF No.: T380B139
WTODESC in ASPPRM1 is not effective. |

| REGISTERED DATE: |
2007/02/13 |
 |
| CATEGORY: |
Monitor |
 |
| CONDITION: |
When WTODESC in ASPPRM1 parameter is specified. |
 |
| PROBLEM DESCRIPTION: |
Regardless of the specification of WTODESC, A-LOG Monitor issues WTO messages with DESC=7. |
 |
| TEMPORARY ACTION: |
None |
 |
| PROBLEM CONCLUSION: |
The programs are corrected to issue WTO messages with a DESC code specified by WTODESC. |
 |
| PREREQUISITE PTF: |
None |
 |
| PROGRAM: |
Many |
 |
| CATALOGED PROCEDURE: |
Many |
 |
| NECESSARY ACTION: |
After stopping A-LOG Monitor, apply the PTF. Restart A-LOG Monitor. |
 |
| AMENDING PTF: |