PTF No.: T380B140
ALOGJLOG does not stop although Stop command is issued. |

REGISTERED DATE: |
2007/03/06 |
 |
CATEGORY: |
A-LOG/VTAM |
 |
CONDITION: |
When A-LOG/VTAM (MODE=MULTI) is used and ALGLVTAM gets an error while receiving data. |
 |
PROBLEM DESCRIPTION: |
When conditions are met, ALOGJLOG hangs up waiting for response from ALGLVTAM.
As a result, ALOGJLOG does not stop when Stop command is issued.
|
 |
TEMPORARY ACTION: |
Cancel ALGLVTAM and ALOGJLOG. |
 |
PROBLEM CONCLUSION: |
ALGLVTAM is changed to display SPM136E message and post ALOGJLOG when an error occurred in receiving data. |
 |
PREREQUISITE PTF: |
T380B126 |
 |
PROGRAM: |
SPVGSUB, SPVLSUB, SPVLCOM |
 |
CATALOGED PROCEDURE: |
ALOG, ALGGVTAM, ALGLVTAM |
 |
NECESSARY ACTION: |
After stopping A-LOG Monitor, link-edit using T380L140. Restart A-LOG Monitor. |
 |
AMENDING PTF: |
None |
 |

|
 |