PTF No.: T380B150
A-LOG Monitor hangs up after S602 abnormal end occurs. |

REGISTERED DATE: |
2008/04/15 |
 |
CATEGORY: |
Monitor |
 |
CONDITION: |
When A-LOG/VTAM (MODE=MULTI) is used and Terminal function or a utility abnormally ends. |
 |
PROBLEM DESCRIPTION: |
Using ESTAE macro, A-LOG Monitor usually recovers from S602 abnormal end that may occur after Terminal function or a utility abnormally ends. With MODE=MULTI, Management Database access subroutine USMSLLNK also issues ESTAE macro and, instead of A-LOG Monitor main program, it gets control when S602 abnormal end occurs. This causes the hang up. |
 |
TEMPORARY ACTION: |
Cancel A-LOG Monitor. |
 |
PROBLEM CONCLUSION: |
USMSLLNK is changed not to issue ESATE macro when it is called by A-LOG Monitor, so that ESTAE macro by A-LOG Monitor will be effective. |
 |
PREREQUISITE PTF: |
None |
 |
PROGRAM: |
USMSLLNK |
 |
CATALOGED PROCEDURE: |
ALOG |
 |
NECESSARY ACTION: |
After stopping A-LOG Monitor, link-edit using T380B150, and apply the PTF. Restart A-LOG Monitor. |
 |
AMENDING PTF: |
None |
 |

|
 |