PTF No.:T380B122
The number of processed job logs or SYSLOGs shown on ALOGUBKS report does not match the number shown on ALOGLBKS report.

REGISTERED DATE: 2004/08/03
CATEGORY: Utility
CONDITION: When ALOGJLOG or ALOGSLOG abnormally ends while storing a job log or SYSLOG, garbage data remains in the Datapool.
PROBLEM DESCRIPTION: When conditions are met, the number of reports counted by ALOGUBKS as shown in 'READ REPORT COUNT=' and the number of reports counted by ALOGLBKS as shown in 'WRITE REPORT COUNT=' do not match.
TEMPORARY ACTION: Regard as normal if the number shown in 'READ PAGE COUNT=' of ALOGUBKS report and the number shown in 'WRITE PAGE COUNT=' of ALOGLBKS report match.
PROBLEM CONCLUSION: ALOGUBKS is changed not to count garbage data so that the numbers match.
PREREQUISITE PTF: None
PROGRAM: BKSUDEL
CATALOGED PROCEDURE: ALOGUBKS
NECESSARY ACTION: After applying the PTF, execute ALOGUBKS.
AMENDING PTF: None
TOP