PTF No.:T380B129
A-LOG Monitor falls into a loop.

REGISTERED DATE: 2005/09/06
CATEGORY: Monitor
CONDITION: When several terminal users and utilities access the Management Database at a same time, and HOTLOG file becomes full.
PROBLEM DESCRIPTION: When conditions are met, A-LOG Monitor searches an empty entry in the HOTLOG file and falls into a loop.
TEMPORARY ACTION: Expand HOTLOG file.
PROBLEM CONCLUSION: The program is corrected not to fall into a loop.
PREREQUISITE PTF: None.
PROGRAM: ABSVIOSM
CATALOGED PROCEDURE: ALOG
NECESSARY ACTION: After stopping A-LOG Monitor, apply the PTF. Restart A-LOG Monitor.
AMENDING PTF: None
TOP