PTF No.:T380B136
ALOGJLOG stores SYSOUT datasets not in order of STEPs.

REGISTERED DATE: 2006/10/22
CATEGORY: Job log storage
CONDITION: When a job log has SYSOUT datasets with FORMS and/or PRMODE attributes specified by OUTPUT statement as well as SYSOUT datasets without these attributes in z/OS.
PROBLEM DESCRIPTION: When conditions are met, ALOGJLOG stores SYSOUT datasets not in order of STEPs.
TEMPORARY ACTION: None
PROBLEM CONCLUSION: A new program ASPLJLGE is created to store SYSOUT datasets in order of STEPs.
PREREQUISITE PTF: None
PROGRAM: ASPLJLGE (New)
CATALOGED PROCEDURE: ALOGJLGE (New)
NECESSARY ACTION: Link-edit using T380L136 and T380R136, create a new procedure ALOGJLGE using T380J136, and create a new parameter DDJLOGSP using T380P136. Start ALOGJLGE.
AMENDING PTF: T380B146