PTF No.:T380B137
SEQ parameter of PRINT statement is not effective.

REGISTERED DATE : 2006/11/16
CATEGORY: Utility
CONDITION: When more than one job logs with the same job name, the same store date, and the same store time are in the Management Database.
PROBLEM DESCRIPTION: When condition is met, SEQ parameter must be specified in PRINT statement for WTRJUTL utility to print a correct job log. But even if SEQ parameter is specified, WTRJUTL always prints the first job log of the selected job logs with same attributes.
TEMPORARY ACTION: Specify only MAKED and SEQ parameters instead of MAKED, MAKET, and SEQ parameters.
PROBLEM CONCLUSION: The program is corrected to use SEQ parameter specification to print the correct job log.
PREREQUISITE PTF: None
PROGRAM: WTRJUTL
CATALOGED PROCEDURE: WTRJUTL
NECESSARY ACTION: After applying the PTF, execute WTRJUTL utility.
AMENDING PTF: None
TOP