PTF No.: T380B157
SCT239E and SCT219E messages are displayed repeatedly by ALOGJLOG.

REGISTERED DATE: 2009/09/14
CATEGORY: Job log storage
CONDITION: When T380B133 is applied and ALOGJLOG processes an incomplete job log in OS SPOOL..
PROBLEM DESCRIPTION: With T380B133, ALOGJLOG holds an incomplete job log instead of purging it. However, there is an incorrect interface to issue Hold command. As a result the Hold command does not work and ALOGJLOG processes the same job log repeatedly.
TEMPORARY ACTION: Cancel ALOGJLOG, hold the incomplete job log, and restart ALOGJLOG.
PROBLEM CONCLUSION: The program is corrected to issue Hold command with right interface.
PREREQUISITE PTF: T380B133
PROGRAM: ASPLJLOG
CATALOGED PROCEDURE: ALOGJLOG
NECESSARY ACTION: After stopping ALOGJLOG, apply the PTF. Restart ALOGJLOG.
AMENDING PTF: None
TOP