PTF No.:T380B161
When 'MENU' command is entered on Terminal function, S0C4 abnormal end may occur.

REGISTERED DATE: 2010/07/27
CATEGORY: Terminal function
CONDITION: When T380B141 is applied.
PROBLEM DESCRIPTION: When condition is met and 'MENU' command is entered on Screen 1.1 or 9.1 of Terminal function, S0C4 abnormal end will occur.
TEMPORARY ACTION: Do not enter 'MENU' command.
PROBLEM CONCLUSION: The program is corrected not to abnormally end.
PREREQUISITE PTF: T380B141
PROGRAM: USLP2
CATALOGED PROCEDURE: Command procedure of A-LOG Terminal function
NECESSARY ACTION: After stopping A-LOG Terminal function, apply the PTF. Restart A-LOG Terminal function
AMENDING PTF: None